How to check whether the VLAN configuration on the two peer-link ports are consistent?
Any MLAG VLAN and non-MLAG VLAN traffic MUST be allowed on MLAG peer-link. Therefore, the VLAN configurations of the peer-link ports on both ends must be consistent. Run the run show vlans command on the MLAG peer devices to check the VLANs of the peer-link port.
For example,
admin@PICOS# run show vlans
VlanID Vlan Name Tag Interfaces
------ ------------------ -------- ------------------------------------------------------
1 untagged xe-1/1/1, xe-1/1/2, te-1/1/2, xe-1/1/3, te-1/1/3
xe-1/1/4, te-1/1/4, xe-1/1/5, te-1/1/5, xe-1/1/6
te-1/1/6, te-1/1/7, te-1/1/8, te-1/1/9, te-1/1/10
te-1/1/11, te-1/1/12, te-1/1/13, te-1/1/14, te-1/1/15
te-1/1/16, te-1/1/17, te-1/1/18, te-1/1/19, te-1/1/20
te-1/1/21, te-1/1/22, te-1/1/23, te-1/1/24, te-1/1/25
te-1/1/26, te-1/1/27, te-1/1/28, te-1/1/29, te-1/1/30
te-1/1/31, te-1/1/32, te-1/1/33, te-1/1/34, te-1/1/35
te-1/1/36, te-1/1/37, te-1/1/38, te-1/1/39, te-1/1/40
te-1/1/41, te-1/1/42, te-1/1/43, te-1/1/44, te-1/1/45
te-1/1/46, te-1/1/47, te-1/1/48, ae1
tagged
2 default untagged te-1/1/1
tagged xe-1/1/3
3 untagged
tagged xe-1/1/3